CERTIFIED SERVER HARDWARE (LEVEL 3 AND 4)
Manufacturer
ModelAppliance TypeProductCertification LevelComment
DellPowerEdge 2950StorageCDP/NSS 6.15, FDS, VTL-SL3Internal storage
GatewayCDP/NSS 6.15/7.00, FDS, VTL-SL3
PowerEdge R510GatewayCDP/NSS 6.15, FDS, SIR, VTL, VTL-SL3
PowerEdge R710StorageCDP/NSS 6.15L4Used with MD1000, MD12x0, and MD 32×0 SAS storage
– FDS 2.10
– VTL-S 5.20 and 7.00
L3Used with MD1000, MD12x0, and MD 32×0 SAS storage
Gateway– CDP/NSS 6.15
– FDS 2.10
– SIR 6.50, 6.51, and 7.00
– VTL 5.20, 5.21 and 7.00
– VTL-S 5.20 and 7.00
L4
PowerEdge R805Storage– CDP/NSS 6.15
– FDS, VTL-S
L3Used with MD1000 and MD12x0 SAS storage
Gateway– CDP/NSS 6.15 and 7.00
– FDS 2.1
– VTL, VTL-S
L3
PowerEdge R900Gateway– VTL 7.00L3
PowerEdge R910Gateway– CDP/NSS 6.15
– FDS 2.10
– SIR 6.50, 6.51, and 7.00
– VTL 5.20, 5.21, and 7.00
L3
PowerEdge T310StorageCDP/NSS 6.15, FDSL3
PowerEdge T710Gateway– CDP/NSS 6.15
– FDS 2.10
– VTL 5.20, 5.21, and 7.00
L4
FujitsuPRIMERGY RX300 S6GatewayCDP/NSS 6.15L3
HPProLiant DL180 G5Storage– CDP/NSS 6.15
– VTL-S 5.20 and 7.00
L3Internal storage.
ProLiant DL180 G6StorageCDP/NSS 6.15L3Internal storage.
Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
– VTL-S 5.20
L3
ProLiant DL185 G5Storage– CDP/NSS 6.15
– VTL-S 5.20 and 7.00
L3Internal storage.
ProLiant DL360 G7Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
ProLiant DL380 G2StorageCDP/NSS 6.15, FDS, VTL-SL3Used with MSA 60 SAS-attached storage
GatewayCDP/NSS 6.15, FDS, VTL- SL3
ProLiant DL380 G5Storage– CDP/NSS 6.15
– VTL-S 7.00
L3
Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
ProLiant DL380 G6Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
ProLiant DL380 G7Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
ProLiant DL385 G2StorageCDP/NSS 6.15, FDS, VTL-SL3Used with MSA 60 SAS-attached storage
GatewayCDP/NSS 6.15, FDS, VTL- SL3
ProLiant DL385 G5Storage– CDP/NSS 6.15
– VTL-S 7.00
L3
Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
ProLiant DL385 G7Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3Requires BIOS version 2010.09.13 (A) (13 Oct 2010)
ProLiant DL580 G2GatewayCDP/NSS 6.15L3
ProLiant DL580 G5Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
ProLiant DL585 G2GatewayCDP/NSS 6.15, FDS, SIR, VTL, VTL-SL3
ProLiant DL585 G5Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
ProLiant DL585 G6Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
IBMx3650Gateway– CDP/NSS 6.15
– VTL-S 7.00
L3
x3650 M2Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
x3650 M3Gateway– SIR 6.50 and 7.00
– VTL 5.2 and 7.00
– VTL-S 5.20 and 7.00
L3
x3655Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
x3850 M2Gateway– CDP/NSS 6.15
– SIR, VTL, and VTL-S 7.00
L3
OracleSun Fire x4200 M2Gateway– CDP/NSS 6.15
– VTL and VTL-S 7.00
L3
Sun Fire x4240Gateway– VTL 5.20, 5.21, and 7.00
– VTL-S 5.20 and 7.00
L3
Sun Fire x4600 M2Gateway– CDP/NSS 6.15 and 7.00
– VTL 5.20, 5.21, and 7.00
– VTL-S 5.20 and 7.00
L3
CERTIFIED SERVER HARDWARE (LEVEL 1, 2, AND PARTNER CERTIFIED)
ManufacturerModelAppliance TypeProductCertification LevelComment
DellPowerEdge R905GatewaySIR 6.50L2
FujitsuPRIMERGY BX400 S1GatewayCDP 6.15L2Failover was not tested and is not recommended.
PRIMERGY RX300 S5GatewayCDP/NSS 6.15L2
PRIMERGY RX600 S5GatewayCDP/NSS 6.15 on Red Hat Enterprise Linux 5.3L2
HitachiHA8000/RS220 (AH)GatewayCDP/NSS 6.00L2
HPProLiant DL360 G5GatewayCDP/NSS 6.15L2
ProLiant ML350 G6Gateway– CDP/NSS 6.15
– SIR 6.5 and 7.00
– VTL 5.2 and 7.00
– VTL-S 5.2 and 7.00
L2
ProLiant DL370 G6GatewaySIR 6.5 and VTL 5.2L2
ProLiant DL385 G5pGateway– CDP/NSS 6.15
– SIR 6.5 and 7.00
– VTL 5.2 and 7.00
– VTL-S 5.2 and 7.00
L2
ProLiant DL385 G6GatewayCDP/NSS 6.15L2
ProLiant DL585 G7Gateway– CDP/NSS 6.15
– SIR 6.51
– VTL 5.21
L2Requires BIOS version 2010.09.13 (A) (13 Oct 2010)
IBMx3650 M3Gateway– VTL 5.21
– SIR 6.51
L2
x3650 M3StorageVTL-S 5.20L2Firmware v12.12.0-0039
x3850 x5Gateway– CDP/NSS 6.15 on Red Hat Enterprise Linux 5.3
– VTL 7.00
L2
IntelSR2612StorageCDP/NSS 6.10L2Intel chassis SR2612 (Timber Creek)
SR4850HW4GatewayVTL 5.10L2
LaCieLaCie 12big Rack NetworkNSS 6.10 with HyperFS 1.01L2
LeftHand NetworksNSM 2060Partner Certified
NSM 2120Partner Certified
NSM 4150Partner Certified
OracleSun Fire x4470 M2Gateway– SIR, VTL-S 7.00L2
Sun Fire x4800 M2Gateway– VTL 7.00L2
StarlineSC-FALC-NSSGatewayPartner CertifiedTested and certified with easyRAID, Infortrend and TopRAID (LSI Engenio) storage systems
SC-FALC-VTL-SGatewayPartner CertifiedTested and certified with easyRAID, Infortrend and TopRAID (LSI Engenio) storage systems
SUNSun Fire V40ZPartner Certified
Sun Fire V65XPartner Certified
Sun Fire X4150Partner Certified
Sun Fire X4200Partner CertifiedOn board LSI SAS 1064 storage controller with driver compiled by FalconStor
Sun Fire X4250Partner Certified
Sun Fire X4270VTL5.10 SP1, VTL 5.20, and SIR 6.50L2
Sun Fire X4270 M2SIR 6.51L2
Sun Fire X4450Partner Certified
Sun Fire X4600Partner Certified
Sun Fire X4640VTL-S 5.20L2

Certification Levels:
L4 – Preferred Hardware – Fully certified by FalconStor’s certification team with the latest GA product version,
L3 – Fully certified for functionality and performance by FalconStor’s certification team, L3 hardware has passed a full suite of functionality and stress tests and is certified with FalconStor EZStart and Web Setup.
L2 – Limited certification by FalconStor’s certification team, L2 hardware is verified with FalconStor EZStart and Web Setup. FalconStor has performed basic testing of this device, including feature functionality and advanced failure conditions.
L1 – Not certified by FalconStor’s certification team but known to work with FalconStor solutions, including the use of the EZStart USB image.
Partner Certified – Certified by a FalconStor partner and sold and supported as part of the partner’s solution.